Siemens

SIPART PS2 Positioner


Email : info@sipartps2positioner.com
 

Siemens Products Range

Siemens CM 1241 RS422/485 - 6ES7241-1CH32-0XB0 (VFD)
Siemens CM 1241 RS422/485 - 6ES7241-1CH32-0XB0 (VFD)
 
Shield connection kit Siemens SINAMICS - 6SL3266-1AR00-0VA0(VFD)
Shield connection kit Siemens SINAMICS - 6SL3266-1AR00-0VA0(VFD)
 
SD-card Siemens SINAMICS - 6SL3054-4AG00-2AA0 (VFD)
SD-card Siemens SINAMICS - 6SL3054-4AG00-2AA0 (VFD)
 
 
 
SIPART PS2 positioner
SIPART PS2 positioner
 
SIPART PS2-Flameproof
SIPART PS2-Flameproof
 

Description of SIPART PS2 Positioner


SIPART PS2 is currently the most widely used positioner for linear and part-turn actuators in a wide range of process industries. This is not without reason. The proven all-round design has a particularly flexible stroke range, intelligent diagnostics, and communicates either via HART, PROFIBUS PA or Foundation Fieldbus. What has been proven so often is certainly the correct choice.

Designed in a Macrolon, aluminum or stainless steel casing, the SIPART PS2 positioners are suitable for all applications. Designed as standard with IP66 or NEMA 4x degree of protection, they are resistant to even the most hostile environments. SIPART PS2 is also available with an explosion-proof enclosure with EExd IIC T4-T6 type of protection.

It can be integrated into the communications landscape via PROFIBUS PA, Foundation Fieldbus or HART protocol. With HART and PROFIBUS, it is also possible to apply SIMATIC PDM to clearly display and document saved trends, histograms, as well as commissioning and operating data.

If you would like to test your solenoid valve or replace its function by a positioner, SIPART PS2 prevents valves from closing or monitors open/close valves as an "intelligent solenoid valve.

By means of a regular partial stroke test, SIPART PS2 ensures that ESD valves (emergency shutdown) and other open/close automated valves remain movable in the event of an emergency. The attached solenoid valve can also be tested.

SIPART PS2 is equipped with comprehensive diagnostics functions as standard. In order to provide advanced warning of expensive failures during operation, our positioners continuously check the actuator and valve.

Benefits of SIPART PS2 Positioner


SIPART PS2 positioners offer decisive advantages
  • Simple installation and automatic commissioning (self-adjustment of zero and span)
  • Simple operation with
    - Local operation (manual operation) and configuration of the device using three buttons and a user-friendly two-line display
    - Parameterization via SIMATIC PDM
  • Very high-quality control thanks to an online adaptation procedure
  • Negligible air consumption in stationary operation
  • "Tight closing" function (ensures maximum positioning pressure on the valve seat)
  • Numerous functions can be activated by simple configuring (e. g. characteristic curves and limits)
  • Extensive diagnostic functions for valve and actuator
  • Only one device version for linear and part-turn actuators
  • Few moving parts, hence insensitive to vibrations
  • External non contacting sensor as option for extreme ambient conditions
  • "Intelligent solenoid valve": Partial Stroke Test and solenoid valve function in one device
  • Partial Stroke Test e. g. for safety valves
  • Can also be operated with purified natural gas, carbon dioxide, nitrogen or noble gases
  • SIL (Safety Integrity Level) 2

Application of SIPART PS2 Positioner


The SIPART PS2 positioner is used, for example, in the following industries:
  • Chemical/petrochemical
  • Power stations
  • Paper and glass
  • Water, waste water
  • Food and pharmaceuticals
  • Offshore plants
    The SIPART PS2 positioner is available:
  • For single-acting actuators: In Makrolon, stainless steel or aluminum enclosure, as well as flameproof aluminum enclosure
  • For double-acting actuators: In Makrolon enclosure, stainless steel enclosure and flameproof aluminum enclosure
  • For non-hazardous applications
  • For hazardous applications in the versions - Intrinsic safety type of protection
    - Flameproof enclosure type of protection
    - Non-sparking type of protection
    - Dust protection by enclosure type of protection

    and in the versions:
  • With 0/4 ... 20 mA control with/without communication through HART signal
  • With PROFIBUS PA communication interface
  • With FOUNDATION Fieldbus (FF) communications interface.
 
 

Downloads for Sipart Manuals and Data Files

 
Drop in Your Immediate Requirement for Best Price
 
 
 
We cater globally including Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Aruba, Australia Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina Botswana, Brazil, Bulgaria, Burkina Faso, Burma, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, China, Colombia, Comoros, Congo, Democratic Republic of the, Congo, Costa Rica, Cote d'Ivoire, Croatia, Cuba, Curacao, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial, Fiji, Finland, France Guinea, Eritrea, Estonia, Ethiopia, Fiji, Finland, France, Gabon, Gambia, The, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Holy See, Honduras, Hong Kong, Hungary, Iceland, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya, Kiribati, Korea, North, Korea, South, Kosovo, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Libya, Liechtenstein, Lithuania, Luxembourg, Macau, Macedonia, Madagascar, Malawi, Malaysia, Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Nauru, Nepal, Netherlands, Netherlands Antilles, New Zealand, Nicaragua, Niger, Nigeria, North Korea, Norway, Oman, Pakistan, Palau, Palestinian Territories, Panama, Papua New Guinea, Paraguay, Peru, Philippines, Poland, Portugal, Qatar, Romania, Russia, Rwanda, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Korea, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Taiwan, Tajikistan, Tanzania, Thailand, Timor-Leste, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda, Ukraine, United Arab Emirates, United Kingdom, Uruguay, Uzbekistan, Vanuatu, Venezuela, Vietnam, Yemen, Zambia, Zimbabwe.
 